IBM PureFlex Systems Sales V2 認定 C4120-782 試験問題:
1. What is the name of the feature in the Storwize V7000 that automatically moves data between SSD and spinning drives when they are in a hybrid pool?
A) Fully Automated Storage Tiering (FAST)
B) Easy Tier
C) Dynamic Tiering
D) Active Cloud Engine
2. A PureFlex prospect is ready to order an enterprise foundation from an IBM business partner. The prospect has a long standing positive relationship with storage purchases from a second business partner. The prospect desires to order the PureFlex from the first business partner and included storage from the second business partner. Which of the following must be discussed with this prospect?
A) The PureFlex transaction may be ordered as requested, as long as the components ship from separate locations
B) The PureFlex transaction may be ordered as requested, but will result in duplicate contracts
C) Separate orders are possible, but the orders would become a Flex System solution
D) The two business partners must share credit and one of them must order all components
3. Which of the following best describes PureFlex?
A) An integrated non-virtualized solution of server, storage and networking.
B) An integrated solution of any current IBM servers, storage and networking components.
C) A set of independently sold components comprising server, storage and networking, integrated on site.
D) An integrated infrastructure with automation and optimization expertise.
4. Which of the following should a seller contact for a quick but detailed comparison of functionality between PureFlex and a UCS solution?
A) Client Technical Specialist
B) IBM Support Center
C) IBM Direct
D) Distributor or CompeteLine
5. A customer is looking at a Flex System solution that would have four x440 compute nodes. The customer is tight on rack space and would like the storage within the chassis. The customer requires a total of 24 ?900GB drives and 48 ?1TB drives. What storage solution will use the least amount of rack space?
A) Flex System V7000 Storage System and two internal expansion units
B) IBM Storwize V7000 with two expansion units
C) Flex System V7000 Storage System and two external expansion units
D) Flex System V7000 Storage System and one internal expansion unit and one external expansion unit
質問と回答:
| 質問 # 1 正解: B | 質問 # 2 正解: C | 質問 # 3 正解: D | 質問 # 4 正解: D | 質問 # 5 正解: C |














644 お客様のコメント
品質保証JPexamはIT認定試験のシラバスに従って、試験問題の範囲を正確に絞って、的中率が99%の最新問題集を捧げます。
1年間の無料更新サービスJPexamは1年以内に問題集の無料更新サービスを提供し、お客様がいつでも最新版の問題集を持つことを保証いたします。もし試験の内容が変更されたら、弊社は直ちにお客様にお知らせします。それに、弊社の問題集が更新されたら、早速メールで最新バージョンを送付いたします。
全額返金JPexamの問題集を利用すると、短時間で勉強しても試験に合格できるのを保証いたします。試験に不合格になってしまった場合、弊社は全額返金いたします。(
ご購入前のお試しJPexamは問題集のサンプルを無料で提供いたします。ご購入前にサンプルを試用して製品の品質を確認することができます。ご遠慮なく利用してください。
